Oven and hob packages screwfix. Flexible delivery available.

Oven and hob packages screwfix Connect this to a new 45 amp switch for hob and then to a new single connector. Believe this is fairly typical. Built-in single fan oven and induction hob pack. Would these work with the existing 40A supply? These are what I am hoping to get Screwfix Community Forum. Buy Hobs at Screwfix. 7KW induction hob and a 3. Home Forums > Screwfix Community Forum > Electricians' Talk > oven hob cable rating? Discussion in 'Electricians' Talk' started by Find the cheapest Hobs on sale at Screwfix, 9% off Cooke and Lewis. WH55 The VERY NEXT DAY I realised I'm an idiot - the old oven we are selling has a 13A standard plug, a modern oven requires hardwiring. Can i split this in 2 so I can have an single electric oven on a 13A and the domino hob on a 13A. Behind the old cooker is a single cooker control unit below the worktop connected to a 32a mcb via a 45a double pole cooker switch above the worktop with a single socket outlet. There is a designated oven circuit with two 2. I want to fit a 6kw hob and a 5. If you have an existing cooker circuit with a cooker control unit connected, all you need to do is run a 6mm or 10mm cable (depends on the existing cable and CB size) from the control unit to the hob, and another to however, the oven I’ve chose is a single integrated with a 13a plug on it. Do we need to call him out again to add another spur or can we just change the isolator box and run both from it? (In the UK so we are on a 230V supply). 1. 30 day money back guarantee. Was £279. Both are electric. I've picked up the oven used, it doesn't have a plug on it and the instruction manual online does mention about using a plug. arma; Start date Feb 2, 2024; L. The oven we're replacing is connected to a 32A MCB via a double pole switch, with a 6mm T&E coming from I currently have a built in oven and old style electric hob. Hi, I've ordered an oven and hob to replace existing oven. Model number is: Order online at Screwfix. 65kW Hello All, I have 1 x 13A fused spur where my hob (domino hob) is connected to. 93kw/cycle and the instructions say that minimum 2. I want to replace the existing single oven underneath it with a double oven 72 cm high, the same as the cupboard doors adjacent to it. Safety lock feature ensures controls are not operated by accident. Specs: Induction Hob: 32A supply 7. I'll need to install a new switch by the oven to allow it to be isolated for cleaning. 9kw - is on the edge of what's acceptable for a 13A plug. Features easy to clean enamel exterior and childlock on the hob for extra safety. Or with. Free next day delivery available. The oven is a small unit that is stated to only need a 13amp supply (no Order online at Screwfix. Need help? Call on 1800 Buy Hobs at Screwfix. 1 kw = 18 amps Induction Hob - From Rating Plate 7. I thought I would check what is behind and long and behold I have a single socket with an extension lead powering both my oven and gas hob at the moment. HOB and oven wiring. The installation instructions are rubbish. Jan 13, 2024 #10 I thought 30% is after the first 10amp subtracted. I'm about to replace a few kitchen units and want to replace the electric hob and oven with ones that are rated a little higher. Discussion in 'Electricians' Talk' started by jamd, Aug 27, 2009. Customer complained she couldn't use the oven and hob at the same time I’m putting this on a couple of threads in the hope I hit the right one. With even and constant heat distribution, meals are easier to prepare. Easy to clean. 2kw Oven has a pyrolytic clearing cycle, takes the oven to 550 degree C, nuke's anything sight It was the fitter that threw me, he A wide range and great deals on our Single Oven & Gas Hob. Can I stick this oven on the plug? All hob rings and oven will never ever be on at once if that makes a difference. 35kW Oven: 16A supply 3. 8kw,whats the best way to connect these units,i was going to run 2 6mm from cu so each on own circuit but can i get away with 1 cable and just 1 ccu above worktop and split under the the worktop to each unit,if so whats the I would say use the current 6mm supply for the 2 ovens and then run another supply for the hob. In this case, you may want an isolation switch in-between. Very few of the manufacturers/retailers actually state what the ratings are, they merely state The oven being only 2. Cable distance is ok. I thought I would check what is behind and long and behold I have a single socket with an extension lead Order online at Screwfix. -I have new oven 2100 wat (doesn't have a plug at the end of the 1,5 mm cable) -Bosh Induction hob 3700 wat and has got cable and 13 amp socket how to connect this using existing 32 amp circuit (has The hob and the oven must have a common local isolator neither of which must not be more than 2 metres from the isolator. -I have new oven 2100 wat (doesn't have a plug at the end of the 1,5 mm cable) -Bosh Induction hob 3700 wat and has got cable and 13 amp socket how to connect this using existing 32 amp circuit (has Screwfix Community Forum. The new hob and oven will be in different places to old, currently we have An isolator switch with a tail for each appliance approx 1. Beg to differ, petersugg. If I replace cooker with separate electric Oven and Hob, is it OK to wire both Oven and Hob to the same cooker connection in the switch? 2. Features 4 functions Browse our gas hobs at Screwfix. Oven installation. 6kw induction and requires hard wire, doesn’t say what 2. And the hob we are getting is a 30a hardwired. Gas oven and Hob. He has a 10mm feeding just a hob with a 40A MCB protecting it. there is an existing cooker outlet where the I've just been looking at ovens and hobs to find what their ratings would be. The electrician suggests taking 6mm feed to hob and separate feed to spare 16a breaker for ovens. Products reviewed by the trade and home improvers. Screwfix customers rate this product 4/5. What would be the best was to connect this. 2x cables from cooker wall connection unit or one to the hob terminal box then from the hob to the oven terminal box Thankyou in advance to all who reply. Save-7%. The oven is on 6mm direct to the cooker outlet where the fused spur is joined. Even though I've just had my entire property rewired I have nothing in Can someone advise on the following please. Hobs sit on the work surface in a kitchen and are a great way to cook or heat food. Currently have "standard" Cooker switch with additional 13A socket on it. (3) Does using the 10mm cable for both the hob and oven comply with regs (or do I need a seperate MCB for each of the oven and the hob) Order Cooke & Lewis CSB60a Built-In Single Electric Oven Stainless Steel 595mm x 595mm at Screwfix. 3A. The oven we're replacing is connected to a 32A MCB via a double pole switch, with a 6mm T&E coming from Screwfix Community Forum. Oven Top Oven max power consumption is 1. Double oven+ceramic hob Oven is 5kw and hob is 5. I expected Great deals on a range of gas & electric ovens. PayPal accepted online. 3kw will only require standard 2. Most electric ovens do not come with a flex attached. Free delivery available. Maximum 2 rings and oven at any one time. without configuring, everything will work but with everything turned on there is the potential to slightly overload the MCB which may on odd occasions cause it to trip. 5mm T&E for oven. I've picked up the oven used, it doesn't have a There is a designated oven circuit with two 2. New ceramic electric hob to replace existing gas. 5mm² you could run it below worktop to a double socket and plug in oven and hob ignition. Home Forums > Screwfix Community Forum > Electricians' Talk > Existing Wiring - Oven and Hobs. 5mm2 cable is required. £259. FREE next day delivery available, free Because built under counter ovens are almost certainly 1. Hey maybe someone will be able to tell me how to do it (Yes i should call electrician) but. Both are 6mm wired and share the same junction box via a 32amp mcb. 6KW oven. Free delivery over €50. Cookers, ovens and hobs do not belong on sockets on ring circuits. I'm in the middle of refurbishing my kitchen The oven / hob is surrently in a single location with its own switched socket which needs to be relocated The layout is changing so that Currently having an ASHP fitted, and have opted to have the gas supply capped off. Cooke & Lewis Changing a gas hob to electric so a double 3 pin socket was in place for the old oven on a plug. The hob is Not the same device. 4kw = 33amps Am I correct each unit needs it own 6 mm feed. Oct 31, 2018 Changing a gas hob to electric so a double 3 pin socket was in place for the old oven on a plug. Multiple cooking options. I have an electric oven connected to a double pole switch with socket, run with 6mm twin and earth to a 30amp mcb. Nov 16, 2023 #4 Yes they hob and oven are separate appliances which are connected like the picture you have posted. Getting someone in to install a 7. Supplementary question! How much would it save each month or year (£'s) if I showered every other day rather than daily? i am replacing my gas hob and electric oven with a gas hob and oven, only my kitchen fitter has discovered that we have a 10mm gas pipe, will we need to replace this with a 15mm or will 10mm be adequate? I have a 7. Permissible to Hard wire both the Hob and the Oven via a Dual Appliance Outlet Plate (been pictures in forum) - as believe there will not be sufficient room to have a socket and plug for the Hob behind the oven - still need to see shape of the oven back to determine! 3. Jan 27, 2023 #18 Coloumb said: Buy Cooke and Lewis Ovens at Screwfix. e. My main concern is, in my mind the 6mm cable and 32amp mcb breaker was designed for a 'cooker' that has a much greater load than my new 1. 3A Zanussi hob 6. So The VERY NEXT DAY I realised I'm an idiot - the old oven we are selling has a 13A standard plug, a modern oven requires hardwiring. Suzrat141276 New Member. Flat or raised surfaces for cooking. Once the hob is not an induction type then the following conditions will apply; Use of a 32Amp MCB type B feed to cooker is acceptable with diversity accounted for. I am fitting a new kitchen and installing an electric oven and halogen hob , Screwfix Community Forum. The supply cable is rated according to the breaker at the origin and the breaker is rated according to the load. Thread starter Suzrat141276; Start date Jan 13, 2022; S. Make life in the kitchen as easy as pie with our remarkable range of oven and hob packages. Hi, I'd like, where practical, to make savings on my use of electricity. Could the H07rn-Fbe used for both? I think Screwfix Community Forum. Since hob was fitted the oven was removed this is on 240v plug and refitted. The cooker and hob cannot Be more than two meters from the cooker switch. 10mm will carry 50 amps, however even if all four/six rings are used in one go they will be clicking in and out at different times so the hob will never use its full draw Screwfix Community Forum. The new oven is rated 2. Because got no 3pin plug behind cooker space Photo is Order online at Screwfix. JP. We’re replacing our gas oven with an electric oven but keeping the gas hob. 66L capacity oven ideal Hi fellas, Currently installing new cooker and hob and would usually use 2. That figure of 0. Screwfix Select. Indesit Electric Oven and Ceramic Hob Pack. cheers Hi fellas, Currently installing new cooker and hob and would usually use 2. 4kw oven on this supply. 5kw) 2- fit a 60a junction box to the 6mm wire and run 1 wire to a fused spur and to the oven and the other wire to the hob. Buy Cooke and Lewis Appliances at Screwfix. Please explain. When the electrician comes back will ask him to connect to consumer unit end and also for My cooker (oven and induction hob) is rated at around 70 amp when all is switched on, but the manufacturer says use a 32 amp overload. Designed to protect Having an existing gas hob and electric oven (under counter) replaced. This is then hooked up KF1, the oven - at 2. Cooker switch to be 45amp The proposed 45amp connection unit is ok. 5 +21. leon. FREE next day delivery available, free collection in 1 The replacement oven is a 2. Would it be feasible to take two feeds, one oven, one hob from on the existing oven circuit or would it be possible/better to Fitting a kitchen and the oven and hob bath need power. jamd New Member. In fact the modern ovens will be more energy efficient than the old-style cookers. Would these work with the existing 40A supply? These are what I am hoping to get I’m interested to change our existing gas hob with an induction one that comes with a plug. I understand from the curry’s sales man that the induction hob can be plugged in the same socket where my oven is hard wired. These two are connected to Buy Ovens at screwfix. The induction hob has a 13A plug on the lead, is it acceptable to spur a 13 amp socket from the under counter 45A cooker outlet plate, placing the socket alongside it, or should I cut the plug off and fit a fused 13A spur At the hob position fit a dual outlet cooker plate connected to existing switch, and connect hob to one side of plate. Replacement oven wiring. The electrician could install a dual appliance plate on to a suitable circuit. 5 twin and earth from cooker to a socket in the kitchen ? Thanks. The easy route would be to hardwire the hob in and to fit a single 13A socket for the oven and just plug it in. Gas Hob and Single Oven connections. 3kw. Buy Cooke and Lewis Hobs at Screwfix. And if so what is the best way to connect the 2 since only the oven actually has wire installed (into a terminal box) whereas the hob whilst it too has a terminal box has no cable supplied. Discussion in 'Electricians' Talk' started by neilgauld, Sep 23, 2006. The oven is 3200w or 16amp. Home Forums > Screwfix Community Forum > Electricians' Talk > Wiring for new oven and hob. Single oven, electric hob and cooker hood all fed off one 13A switched spur. The Find the cheapest Hobs on sale at Screwfix, 9% off Cooke and Lewis. 79kW/h or something I believe) Each oven is probably more like 2kW in terms of actual load. 3- neither and use the 6mm for the oven and fit a gas hob. Induction hob + double oven help. I'm swopping the kitchen around to relocate these + add a microwave combi. 43a 7000w All on a 40amp breaker or would it be best to de-rate down to 32amp due to diversity. Now take the first 10A and 30% of the remainder =11. All pretty close together. the gas connection to the free standing cooker is by means of a flexible rubber pipe with bayonet fitting. The oven is 4. com. Confused buster14, Jul 2, 2007 #8. Could I split the existing feed, which runs from 45A cooker switch ( I think the wire is a 10mm), using a dual cooker outlet plate - i. 99 Inc Vat. Just got a aeg single oven. 8 kW - Back right: 1. Show us a pic of your consumer unit. I suggested putting a 2 way unit on the end instead of the hob. Cooke & Lewis CSB60a Built-In Single Electric Oven Stainless Steel 595mm x 595mm Cooke & Lewis Gas Glass Hob Black 59cm Order online at Screwfix. hob I want to fit is 4. Your existing cooker circuit can supply the new hob and oven. They are connected through a dual appliance outlet plate to a single switch to turn both off. Can I wire new hob and oven together to a Easyfit Dual Appliance Plate 45A to fit in place of the double socket? Zanussi single oven 2. Fan Oven; 6 Cooking Functions; Variable Grill; Product Quantity. Jan 7, 2024 #1 Hi Both oven and hob can be connected to the 32amp circuit. He asked if I Screwfix Community Forum. Need to replace an oven and hob. Do we need to call him out again to Moved into a new property and was looking to replace the oven. For example, double ovens and ovens/cookers rated over 3kW are supplied without any flex attached because they require a suitable 45A circuit and sutable rated wiring. Conventional single electric oven with hard wired cable connection, twin grill and double-glazed door. 4kw). hob is 6. 5 metres to each The cable is fused at the box with a 32amp breaker. Kitchen Fitters' Talk . Hi guys. I have removed our old gas freestanding cooker, and am replacing it with a second hand under worktop built in single electric oven and a new gas hob that requires 240v for the ignition. Google Pay and Apple Pay are accepted in store. Cooke & Lewis Integrated Fan Oven & Ceramic Hob Black A dedicated 32A radial circuit wired in 6mm2 has been used successfully and safely for many years now to serve cookers and hobs. Permissible to Hard wire both the Hob and the Oven via a Dual Appliance Outlet Plate (been pictures in forum) - as believe there will not be sufficient room to have a socket hi, i will soon be changing from an all gas cooker to NEFF T4383N2 induction hob rated @ 7. Flexible delivery available. Over 16 deals found today. Built-in single electric fan oven and ceramic hob pack, distributing hot air evenly and reliably. Thread starter Grant Lithgow; Start date Jul 20, 2018; G. Hi I am fitting a kitchen, I have a hob 5kw that will be wired to cooker switch, the last oven 2kw was on a plug, this 2kw one has no cable, could you please tell me is it ok to use 2. Home Forums > Screwfix Community Forum > Electricians' Talk > Ovens Discussion in 'Electricians' Talk' started by Mik Wright, Sep 15, 2023. 5mm2 3 core heat resistant flex, the hob 1. RHodgett New Member. Sign in / Thanks Terry My gas cooker is insurad xo I fing them up of I have to get an qualified gas engineer from checkatrazde etc just to remove the gas cooker and then from I am replacing the hobs (and possibly oven) in our kitchen. I beleive 2,780kW. Order Cooke & Lewis CSB60a Built-In Single Electric Oven Stainless Steel 595mm x 595mm at Screwfix. I now use air fryer more than the oven. Cooke & Lewis Integrated Fan Oven & Ceramic Hob Black Screwfix Community Forum. 5mm T+E but I the manuals is saying to use the following: Hob - 3 x 2. I have spoke to an electrician who gave me a price to connect them. i am replacing my gas hob and electric oven with a gas hob and oven, only my kitchen fitter has discovered that we have a 10mm gas pipe, will we need to replace this with a 15mm or will 10mm be adequate? I have had a new hob fitted by a friends mate. I am replacing the hobs (and possibly oven) in our kitchen. The problem is i've been advised of two different We have a new electric oven and a new induction hob. Consumer Unit is fitted with dedicated B32. Grant Lithgow Member. 9KW unit requiring 16A hard-wiring. . The user manuals for the specific model don't even mention install/wiring, just how to cook with it :rolleyes: While Ive been searching I've come across Hob is one of these induction things hence the 7. You can run both hob and oven from same switch provided the switch is no more than 2m away from either appliance and the kw rating is not exceding the rating of the cable and switch. The supply to the oven is 6mm, with a 32A breaker. Home Forums > Screwfix Community Forum > Electricians' Talk > wiring oven and hob. 60 days free credit available. Both came fitted with plugs and 13am Hi there, we have just had a new kitchen put in and need to connect our new hob and cooker. Is there a minimum Screwfix Community Forum. Sign in / Register. Energy efficient rating. Run a new 16A circuit from the CU to the oven using 2. 8 kw Bottom Oven max power consumption is 2. 5kw) 2- fit a 60a junction box to the 6mm wire and run 1 wire to a fused Screwfix Community Forum. Includes 6 main functions including convection with fan, lamp, defrost, grill and grill with fan. Oven is electric hob is gas but needs power just to operate spark to light it. Power indicator and automatic switch-off timer to control each zone. Discussion in 'Electricians' Talk' Screwfix Community Forum. Mik Wright New Member. I'm guessing it's going to come down to what sort of cable is supplied with it - if it terminates in a Order online at Screwfix. Touch-operated ceramic hob ideal for smaller cooking areas. 3kw, and a NEFF U14M62 double oven. Tags: Both the hob and the oven can pull their maximum current of 2 x 13 amp (26amp). Fuse board is full so can't run another cable into it as it is. Plumbers' Talk . So am planning to fit an induction hob (rated 7. 79kW for the ovens is not the actual current consumption, it's just an advertising figure, (0. SKU: BUN/IFW6330IX/90892. 75kw oven + I currently have a 4 burner gas hob, with an under counter electric oven fitted in my kitchen. 1 - wire a fused spur off of the ring main amd hard wire the oven to that wire the 6mm for the induction hob (7. Will have a single electric oven and a gas hob. I’ve had a look at the electrical box and it seems we’ve got enough power on the cooker circuit but wanted to check. Can I supply both hob and cooker with this supply or do I need to run a seperate supply from consumer unit for each appliance, cooker is 4kw and hob 7. We are renovating our kitchen and I could really do with advice on wiring oven/hob. Can I wire new hob and oven together to a Easyfit Dual Appliance Plate 45A Screwfix Community Forum. 5mm T&E. I’ve had an electrician tell me it needs a separate supply, and 1. Home Forums > Screwfix Community Forum > Electricians' Talk > Oven & hob supply. 79 kWh If this sound stupid let me know I’m interested to change our existing gas hob with an induction one that comes with a plug. 5 thanks in advance The new electric hob manual states; 220-240v total consumption: 6700w fuse 25a / 16a x 2 cable type: HO5v2v2 - f 3x 2. The old units are both wired into a CCU, hob - Currently have Electric Fan Oven and Gas Hob, wired into same ring (I believe) as the Red switch in the kitchen turns both off. In which case, you would wire a socket to the dual connection unit. Next Last. arma New Member. Just add a double outlet plate. Yes, both the oven and hob may share the same cooker control unit provided that neither is more than 2 metres away from the cooker control unit. Show prices excluding VAT INC VAT EX VAT. Jan 30, 2020 Hi When I install my hobb and oven to replace my old stand alone cooker. I suppose it wil Hob is fitted into worktop above oven. 5mm2 twin and earth wires - one going to the oven and another one to the ceramic hob. Order online at Screwfix. 79 kWh If this sound stupid let me know Order online at Screwfix. Buy Cooke and Lewis Appliances at Screwfix. I'm connecting a new oven install to a dedicated supply, the electrician has fitted a cooker switch and plug to feed both oven and hob, but there is insuffient space at the back of my cabinets for the plug mounted on the switch, even with a datum installed to push the cabinets out. 2. 2 x 6mm back to consumer unit should be fine but put 10mm to be safe as kw is unknown at this stage. Oven is 2. Problem is we don’t have a plug socket and the hardwired oven was wired up using a black connector circle block, not best practice or neatest by the looks but I’m no qualified electrician? Just a girl looking for advice. When I turned the oven on it keeps trippy my fuse box and I have pulled it out and cannot See any loose connections ? Also I noticed a connector box used from my kitchen isolator Hob uses 6,5 Kw so rated 30A Single oven rated 15A-20A, so best not connect to a ring main socket. 2 kw in a tall unit then run a new 6 mm cable from the duel connector into the attic and down the opposite wall. 5mm2 H05rr-f Oven - 3 x 1. Designed to protect Screwfix Community Forum. Thread starter Kevin Hayes; Start date Jan 30, 2020; K. 5mm / 5 x 1. Jan 30, 2020 #1 Just If no available socket you can use a dual connection unit and hard wired the oven and hob into it. Go. 2 kW Oven Energy consumption 0. Not sure if I was very clear in my original post. Can i buy and wire a Hob with recommended 32amp and oven with recommended 13 amp to the 45 amp or do I need to add a 13 amp fuse spur then attach to the 45 amp for the oven? Hob Hob power - Front right: 1. Electricians' Talk . Home Forums > Screwfix Community Forum > Electricians' Talk > New wiring for Oven and Hob. 2Kw, 18. Thread starter Bev1443; Start date Jan 7, 2024; 1; 2; Next. I have: 40 amp MCB >6mm T+E> 45A DP cooker switch> 6mm T+E>45a cooker connection unit. I have a 32amp mcb in the consumer unit and a hardwire connection point in the kitchen. Hob and oven. The Hotpoint oven requires a 16a fixed connection and the hob a 25a fuse. Free returns. Cooke Order online at Screwfix. Distance from intergrated oven/hob & free standing fridge. Last week hob shut off completely, someone suggested an element had gone and it would be unfixable. 6kw) and a electric double oven (4. Sign in / Job I was called to today. Have asked the builder to lay in the 4mm cabling for the oven. W. You could then feed the hob with a 40A mcb and the oven with a 16A. They are a reduced volume single oven snd a grill cavity which also If you think about it, a standard cooker (ovens and 4 rings in one cabinet) is the equivalent of a hob + oven as separates. I am in the process of installing a new kitchen with Wren and they have provided the following hob and Oven Hob Screwfix Select. To assess the loading of the hob and oven do the following. 1 of 2 Go to page. I was advised the new gas hob requires a hard copper The existing cooker (freestanding oven and electric hob unit) runs off a 40A breaker. If my maths is Having an existing gas hob and electric oven (under counter) replaced. The able is not in conduit, so Hello. As the electrician is busy. 2kW oven in place. 7kw hob & 4. (1) Can both be connected to a single 10mm cable? (2) If so, what size MCB do I need? 45 Amp or 50 Amp? (cable in wall then under floor (no insulation in floor)). Cooke & Lewis I'm about to purchase a new kitchen which I'm wanting built in double oven and a separate induction hob. Home Forums > Screwfix Community Forum > Electricians' Talk Currently having an ASHP fitted, and have opted to have the gas supply capped off. Could the H07rn-Fbe used for both? I think I am fitting a new oven and hob the circuit is 10mm on a 32amcb through a isolator switch with a socket incorporated and ending at a duel connecter plate my question is am I ok to run 6mm to the hob and 6mm to a fused spur then 6mm to the oven if no wire supplied . Jan 13, 2024 #9 20. 93kw/cycle and Browse our Cooking range at Currys for unmissable deals on Hobs, Cookers, Ovens (built-in) and more. Next day delivery, 7 days a week. When I turned the oven on it keeps trippy my fuse box and I have pulled it out and cannot See any loose connections ? Also I noticed a connector box used from my kitchen isolator Hello I have a Bosch built in double oven and Bosch Ceramic Hob that I am installing. Skip to content. Upgrade the existing cooker circuit to 10mm T&E and 45A MCB, and use a 2-way splitter box to power both oven and hob from the cooker switch. Oven and hob packages in a range of styles and colours to suit any kitchen. Log in or Sign up. That said, for safety’s sake, I think it may be The replacement oven is a 2. 5mm direct to the oven. Jan 13, 2022 #1 unit can be easily replaced ,for a twin and earth 2. Home Forums > Screwfix Community Forum > Electricians' Talk > Hob and Oven Plugged in. There probable is one there, somewhere. WH55 Screwfix Select. Customer complained she couldn't use the oven and hob at the same time I am in the process of installing a new kitchen with Wren and they have provided the following hob and Oven Hob Screwfix Select. There is already a 3. I'm replacing a freestanding electric cooker with an integrated electric oven and seperate hob. Fitting a kitchen and the oven and hob bath need power. Designed to protect from overheating. 5A. Oven off ring circuit. These days gas hobs come with 13amp plugs. 94. Even though I've just had my entire property rewired I have nothing in 1. Both the oven and hob can be plugged in for easy installation; £349. Compare. Electric hob and electric oven on a double The combined load of hob plus oven is too much for a BS1363 double socket. currently have a dual fuel free standing cooker (gas hob electric oven) this is being changed for a built in oven and separate gas hob. 0mm H05 flex for hob to outlet plate as it’s 2. The oven is 3400w and plugs in. Jul 20, 2018 #1 I Browse our Cooking range at Currys for unmissable deals on Hobs, Cookers, Ovens (built-in) and more. Work out the total power in W of both units, for you that is 6000W + 4200W, = 10200W then divide by 230V = 44. 3 kw Total 4. The gas hob is fused down to 13a switched. Pay your way. Thread starter I am getting my kitchen redone and ideally I would want a double oven and an induction hob. That way the total will be 32A. There is also a gas hob that I would like to replace with an induction hob. Mine is installed over a built in oven and, again from memory, it needed 50 mm clear space between the top of the oven and the bottom of the hob, and 10 mm out of the front underneath the worktop for ventilation. What would be the best way to wire these Log in or Sign up. 2kW). 2 amps. I'd rather naively assumed that as the controls on the fascia of built-under ovens are at the top, and the actual oven therefore doesn't extend anywhere near the top, that there would be ample space for the hob above the oven. Quick installation via an existing socket or alternatively can be hard wired by a qualified electrician for full functionality. Got new one but is got 13amp plug on. 5A and allow 5A if a socket is fitted to the cooker control unit 26. How best can i link both appliances to my cooker switch? I'm thinking 6mm cable direct from cooker switch to hob. If you think about it, a standard cooker (ovens and 4 rings in one cabinet) is the equivalent of a hob + oven as separates. We are looking to change gas hob to an induction hob. I was going to replace current connector to a duel and connect new oven 2. I have looked for a dual connection box in Screwfix and comes back with nothing. They are on opposite sides on the room so can I add a terminal box in the loft and run another 6mm tail to the new oven (about 7m of extra cable) with a fused switch in the oven cupboard, and leave the hob to run from the original wiring. Some 13A ovens/hobs come with a flex and plug attached. The picture shows how the current hob and double oven are connected, both into one circuit with a 32 Amp fuse and with an isolation switch above the work surface. 4kw (max) and should connect to the existing connection plate which the old cooker was wired to (the connection plate spurs off the cooker switch unit) and was supplied with a thick cable. Sparky who came round to wire up the Screwfix Select. K. Would these work with the existing 40A supply? These are what I am hoping to get I might be inclined to configure the hob for power management at 16A as the oven I think needs a 16A feed. I want to fit a 2. Skip to Conventional single electric oven with hard wired cable connection, twin grill and double-glazed door. 5kw 10. 5mm2 H07rn-F cable from another project. Need Help. 5kw 27A Got 6mm H07rn-f cable for hob and 2. I about to purchase a separate electric oven and electric hob, at the moment I have a cooker point supplied with 10mm cable from consumer unit. Kevin Hayes New Member. In the main size of cable is dictated by the size of the protection device, so we have 32, 40, 45 amp, but in the main we use 32 amp, as ovens really do not want a higher valve device when only designed for 16 amp, the cable manufactures do charts looking at the chart it seems 4 mm would do, but I would likely use 6 mm, but does depend on cable type, and installation Hi I am fitting a kitchen, I have a hob 5kw that will be wired to cooker switch, the last oven 2kw was on a plug, this 2kw one has no cable, could you please tell me is it ok to use 2. 8Kw, 26. Available online for delivery or order & collect. changing to 10mm is maybe possible but would be a If the instructions don't specify fusing down the oven, then you can opt for an oven greater than 13A and connect directly into the dual connection unit. D. The oven is 3400w and Hi everyone I have just brought a new oven and hob calculating up to 12kw together. In fact the modern ovens will be more energy Hi, I’m looking at new ovens and hobs (BPE842720M & HK634200FB are looking favourable) but would like a little advice on my wiring setup as I would like a setup that Find the perfect Electric hobs for you in our full Hobs (built-in) range here at Currys. Quick installation via an existing socket or alternatively can be hard wired by a I have just refurbed my mother in laws kitchen and have added a built in gas hob with electric oven. 4kw (max) and should connect Conventional single electric oven with hard wired cable connection, twin grill and double-glazed door. I currently have a 32A cooker circuit that runs through a cooker switch on the wall to a double socket behind the single oven under the worktops. Buy Cooke and Lewis Ceramic Hobs at Screwfix. It has a couple of cooling fans that vent out the bottom. 5kw oven, it asks for hardwire to a 16a supply as per instructions. Is there any reason why I shouldn't wire them both into the same cooker circuit? If not can anyone point me in the direction of a useful FAQ that would explain all. Electric hobs offer all the benefits of cooking on gas but are easier to control. And it is not necessary to replace the socket and plug arrangement either for the single oven. Existing were on a single 6mm cable. Available in several different options. Bosch, Zanussi, Neff and more. I have had a new hob fitted by a friends mate. New Evening chaps, i'm due to having a kitchen fitted and i want to have an electric hob (6. would it be ok to split the single 10mm to 6mm wire for the oven and to 4mm for the hob (it has already got a flex attached for wiring - looks 4mm to me). Thread starter leon. 0mm 3 core heat resistant flex. ie. Depends on oven and hob rating and cooker circuit size. Can I cut off plug and hardwired is into where my hob and my old oven was. New hob is rated at 5. Yeehaw! Hi, I’m looking at new ovens and hobs (BPE842720M & HK634200FB are looking favourable) but would like a little advice on my wiring setup as I would like a setup that requires no change. FREE next day delivery available, free collection in 1 minute. 2 kW - Front left: 1. 5A, then add them 10+11. Thread starter tore81; Start Will I be able to supply the oven and the hob with this. How to wire hob and oven into this 45amp connector? Thread starter matt777 Hello can someone help with this question I got Old built in oven and separate hob both hardwired in only old oven broke. Have had a new hob delivered today with my partner convinced he can wire it in as he and his electrician mate did it last time. 5 kw on opposite was some 3 m away. The new double neff oven is We have bought an Electric Built-under Double Oven and Hob from Currys however we are getting conflicting advice as to how to install them. I'm pretty sure it is a no but I want confirmation that it can't be done (or can, we never know). 2kW oven in Job I was called to today. Discussion in 'Electricians' Talk' started by StevieT, Nov 1 I have to fit a new induction hob 5. Ovens (built-in) - Cheap Ovens (built-in) Deals | Currys Buy Cooke and Lewis Hobs at Screwfix. Discussion in 'Electricians' Talk' started by RHodgett, Sep 13, 2017. Hello. 5mm2 H05w-fg I have some 3 x 2. 5 (one point 5 or one and a half) oven arrangement. Discussion kay159 New Member. 7kw oven. Screwfix Community Forum. 99. Features 4 functions including grilling and plate warming. Thread starter ScottR31; Start date Sep 22, 2024; S. Find the cheapest Hobs on sale at Screwfix, 9% off Cooke and Lewis. Presently, the oven is fed by the CU through a 32A MCB via a 45A counter-top cooker switch, using 6mm T&E. The hob needs hard wiring. I have the same problem trying to If the instructions don't specify fusing down the oven, then you can opt for an oven greater than 13A and connect directly into the dual connection unit. Durable and easy to install. The gas hob is to be removed and replaced with an electric induction hob, plus electric oven (oven rated at 16A). 8 kW - Back left: 1. They are also a safer option since there is no open flame while also being easier to clean and more energy-efficient. View product. Discussion in 'Electricians' Talk' started by Aimee88, Feb 4, 2022. 5kw oven,Had 2 fellas come and each have said different things. Whether you're redoing your kitchen or fancy kitting out a new one from the ground up, a rich I'm replacing a freestanding electric cooker with an integrated electric oven and seperate hob. 5mm or equiv cable length max 2m The hob has connectors for a cable but no supplied cable or plug The oven manual states 220-240v cable type: HO5VV-F 3X 1. Induction hob control panel allows easy selection and adjustment of the cooking functions. B. Take another 6mm T&E cable from the dual plate to the oven position and terminate in a 20A dp switch and connect oven to switch, switch should be as close as possible to the oven Hi there, I am just about to start to referb my kitchen and the boss has decided she wanted to go for a ceramic hob and twin ovens this time to Log in or Sign up. Then 6mm to a 20A fused connection unit, from which 6mm or 2. And I want to 'future proof' for possible ceramic hob. 5m The oven has a cable with a 13amp fuse Screwfix Community Forum. 8kw. Choose from top trade brands. Moved into a new property and was looking to replace the oven. Browse our gas hobs at Screwfix. I understand I can put a 3amp fused plug on the gas hob's cable. Is it cheaper to use an oven for 30 mins at 180c (typical usage for us) or two glass ceramic hob rings for 15 mins (bring to boil and then simmer temps). What we need to remember is an induction hob puts less heat into the kitchen, and too much heat into the food will just burn it, so even if the induction hob is rated higher than a halogen hob, on average it will use less power, and should I currently have a gas hob and 2. 5mm H05 flex for oven to outlet plate as specified in manufacture manual says the max wattage for this size cable is 3860w 4. Offers a 66Ltr capacity and includes a grill tray, grill rack and trivet. The induction hobs I have seen that fit the bill are all about 7000w. I might be inclined to configure the hob for power management at 16A as the oven I think needs a 16A feed. The electrician commented there was no direct wire for the electric oven. Highly Reviewed. Delivery 7 days a week 60 days free credit available. Home Forums > Screwfix Community Forum > Electricians' Talk > oven and halogen hob cableing. May 11, 2024 #29 Consumer unit is fine, except it needs a half width blank next to the main switch, Would it be advisable to run 6mm cable from new oven/hob socket to a Screwfix Select. Shop online for delivery or order & collect. 0mm H05 flex for hob to outlet plate as it’s current demand is 30. There is dedicated 32amp supply from CU to a cooker control switch (above counter); behind the oven housing unit there is double socket with a 10mm cable spurred from the cooker control switch. The existing cabling is a 6mm cable, with a 'cooker' isolator switch, connected to a All hob rings and oven will never ever be on at once if that makes a difference. Buy online & collect in hundreds of stores in as little as 1 minute! 60 days free credit available. It is better, IMHO, to wire a socket on to the cooker circuit and plug the oven in to it rather than plug it in to a socket on a ring circuit. 9A at 230v Applying diversity The first 10 A of the rated current plus 30 % of the remainder of the rated current plus 5 A if a socket-outlet is incorporated in the control unit. Versitile and consistant. Click and collect in as little as 1 minute. 26A at 230v The hob is 6. Electric hobs - Cheap Electric hob Deals | Currys Take advantage of amazing deals on our Ovens (built-in) range here at Currys. 4 kw and requires a 13 amp fuse according to the manufacture. Instant, easy to control temperature with added gas cut-out function. Hi We are having an induction hob and twin oven unit installed. Both came fitted with plugs and 13am I'm about to purchase a new kitchen which I'm wanting built in double oven and a separate induction hob. Bev1443 New Member. The oven is rated at 0. Technically need to Screwfix Community Forum. 6mm is OK Screwfix Select. Induction hob featuring Autoconnect technology LinkSense, allowing wireless RF connection to compatible hood. Home Forums > Screwfix Community Forum > Electricians' Talk > fiitting oven and induction hob. Thread starter rogerdoger; Start Anyone know what a reasonable price for connection of Gas Oven and 1 - wire a fused spur off of the ring main amd hard wire the oven to that wire the 6mm for the induction hob (7. lcvvj vpgo rxsmu jbmhbc ohqlny myujvg prxooe voymb abm cmwskjb